General
KYN61-40.5KV removable AC metal-clad switchgear(short for switchgear as below) applies to 40.5KV, 3 phase, AC and 50/60Hz electrical power network for receiving and distribuling power energy and also for control, monitor and protection. It is applicable in general power system and occasions with frequent operation. The product conforms to GB 3906 “3-35KV AC Metal Enclosed Switchgear” . GB/T 11022 “The common technical clauses of High Voltage Switchgear and controlgear Standard” , DL/T 404-1997 “Order Technical term of Indoor AC High Voltage Switchgear” and IEC-298 “1-52KV AC Metal Enclosed Switchgear and Controlgear standard”.
Working condition
● Ambient temperature:-25℃~+45℃, daily average: ≤35℃
● Altitude: 1000m( Standard); can up to 4500m for special ordering;
● Relative humidity: daily average ≤ 95%, monthly average ≤ 90%;
● Earthquake intensity≤8 degree;
● Applicable occasions should be free from corrosives, inflammables and vapor.
● Ambient temperature:-25℃~+45℃, daily average: ≤35℃
● Altitude: 1000m( Standard); can up to 4500m for special ordering;
● Relative humidity: daily average ≤ 95%, monthly average ≤ 90%;
● Earthquake intensity≤8 degree;
● Applicable occasions should be free from corrosives, inflammables and vapor.
Product difinition
MODEL: | KY N 61 □- 40.5 /T 2000-31.5 | ||||||
KY | N | 61 | □ | 40.5 | T | 2000 | 31.5 |
Metal-clad | Indoor | Model number | A: Middle-plated;B:floor type; C: VD4/HD4 type | Rated voltage (KV) | Spring operating mechanism | Rated current IA) | Rated short circuit breaking current (KA) |
Product feature
The switchgear is an assembly unit and the circuit breaker adopts handcart floor model. It owns simply change and well exchange after equipping with advanced composite insulation vacuum circuit breaker.Lead screw nut propulsion mechanism is installed in the handcar frame for preventing from fault operating and damaging propulsion mechanism, the handcart can be remove easily; All of the operation steps can be carried out at closing condition; It is compulsory locking among main switch, handcart and panel door to meet five protection; wide space for connecting several cables in cable cubicle.Earthing switch is used in earthing and loop short circuit, protection degree of enclosure is IP3X, IP2X under opening condition.
Structure feature
The switchgear divides into enclosure and handcart, the enclosure is made of aluminum-zinc plated seel sheet after processed by CNC machine and muli-bending, then is assembled with bolts. So it has strong mechanical strength and can guarantee the neatness and good appearance. It consist of relay compartment, handcart compartment, cable compartment, protection degree is IP2X when CB handcart is on opening and testing position.
The switchgear is metal-clad removable type, main circuit adopts composite insulation processing, emergency spreading to other parts. CT and earthing switch are mounted in cable compartment and busbar compartment. The protection degree of enclosure is IP3X, the protection and large space for several cables.The structural design of new completely insulated VCB or SF6 CB and spring operating mechanism is integrated console model with such excellence of well exchange and simply change.
Technical specification
Item |
Unit |
Data |
|
Rated voltage |
KV |
36/38/40.5 |
|
Rated current |
A |
1250,1600, 2000, 2500 |
|
Rated frequency |
Hz |
50/60 |
|
Rated short drcurt breaking current |
KA |
25.31.5 |
|
4s rated short time withstand current |
KA |
25,31.5 |
|
Rated short drcurt making current (peak) |
KA |
63.80 |
|
Rated peak withstand current |
KA |
63,80 |
|
Insulation level |
Rated lightning impulse withstand voltage |
KV |
185 (phase to phase: 215) |
Main circuit Imin power frequency withstand voltage |
KV |
95 (phase to phase: 1101 |
|
Auxiliary circurt Imin power frequency withstand vohage |
KV |
2 |
|
Outline dimenslon(W)*(D)*(H) |
MM |
1400/2800/2600 (GPN1 type) 1200/2600/2400 (For VD4/HD4 type) |
|
Protection degree |
IP3X (compartment IP2X) |
||
Weight |
KG |
1000-1850 (GPN1 type) 850-1850 (For VD4/HD4 type) |