Indoor H.V. Vacuum Load Break Switch FZRN25-12D/ FZN25-12D

Short Description:

Certification: 3C

Place of Origin: Zhejiang, China

Brand Name: Timetric

Model Number: FZN25-12/630A

Product name: Load switch

Material: Epoxy resin

Color: red

Rated voltage: 12KV

Breaking current: 50KA

Rated current: 630A

MOQ: 1 pcs

Package: Wooden box

Type: High Voltage

Certificate: ISO9001


Product Detail

Product Tags

General Description

FZRN25-12D series load switch and its combination of electrical appliances, including air pressure type load switch and vacuum load switch two categories, is the digestion and absorption of foreign advanced technology, combined with our user requirements to improve,bv our factory to design. develop and become. Is a new generation of hiah voltage electrical products applicable to the city power grid construction and transformation needs. Performance of the GB/T3804″3-63KV AC high yoltage load switch” and GB/ T16926 “AC high voltage load switch fuse combination” standard entrusted to the China National Quality Supervision and inspection center of high voltage apparatus according to the latest national standards to conduct a comprehensive test, the main product is the domestic leading level of similar products. Distribution system, the product is widely used in factories.schools, residential areas, high-rise buildings and other three-phase alternating current, voltage 10KV,rated frequency 50Hz,as the acceptance and distribution of electric energy use, and can be used for ring switchgear. box type substation. opening and closing of the power distribution equipment.

The normal use of the environment

The normal conditions of use load switch and switchgear is suitable for the following.if the actual use of the environment condition is diferent from the normal conditions of use.shall be borne by the user and manufacture of both parties through consultation. The ambient temperature: 40 ℃ lower limit:-25 ℃;

Altitude: not more than 1000M:

Relative humidity: daily average value is greater than 95%, on average less than 90%.

Saturated vapor pressure: daily average value not more than 2.2×10-3Mpa,monthly average value not more than 1.8×10-3Mpa; Installation location: no fire, explosion, pollution,chemical corrosion and frequent violent vibration of the place;

Earthquake intensity: no more than 8.

Pollution grade: II

Structural characteristics

Load switch for the frame structure,unique structure compact, integrated isolating switch,load switch, fuse, grounding switch is one of the high voltage electrical products.

lsolating switch for direct drive type, motion direction and motion parallel to the direction of the vacuum interrupter. Separate switch has obvious partition port security barrier,when the grounding switch on at the same time. and the safety barrier grounding switch static contact linkage automatically charged (closed busbar chamber), repair or replace the fuse is absolutely safe.

lsolating switch,load switch on-off sequence mechanical procedure quarantee. Closing operation. isolating switch. load switch it on first after closing. The opening operation, load switch off after the first isolating switch gate. A mechanical interlock to prevent mis-operation between load switch and earthing switch.

The load switch with lock. can easily switch cabinet and the switch when the door open or the door interlock, door unlocked. load switch can not operate, when the grounding switch does not switch on, the door cannot be opened. Load switch for electric, manual,can realize remote control.

Technical Parameter

NO.

ltem

Unit

FZN25-12 /T630-20 Load break switch

FZN25-12D /T630-20K Load break switch(Can open cut short circuit current)

FZRN25-12D /T125-31.5 Load break switch

1

Rated voltage

kV

12

12

2

Rated frequency

Hz

50

50

3

Rated current

A

630

125

4

Rated short time withstand current(2s)/peak value

kA

2050

5

Ratedshort-circuit makingcurrent

kA

50

80

6

Ratedshort-circuit breaking current

kA

31.5

7

Rated resistive load dropout current

S

630

8

Rated closed loop dropout current ‘

A

630

9

^ated cable recharging dropout current

A

10

10

10

Interrupting no-load transformer capacity

kVA

11

Rated interrupting take over current

A

12

Power frequency withstand voltage, between poles, to earth/isolating distance

kA

42/48

42/48

13

Power frequency withstand voltage, between poles, to earth/isolating distance

kV

75/85

75/85

14

Short time withstand current peak of earth switch

kA

20/50

20/50

15

Power frequency withstand voltage of auxiliary loop

V

2000

2000

16

Contact clearance of load break switch

mm

8± 1

9±1

8±1

17

Average opening speed ol load break switch

m/s

1.0±0.2

10 ±0.2

1.0±0.2

18

Average closing speed of load break switch

rrVs

0.6±0.2

07±0.2

0.6±0.2

19

Different period of three-phase break and close brake

ms

≤2

2

20

Jump time of contact closing

ms

≤5

≤5

21

Rated contact pressure

N

650

≤650

22

Closing time difference of disconnecting swilch and load break switch

ms

10

≥10

23

Opening time difference of disconnecting swilch and  load break switch

300

≥300

24

Opening time of triggering the imAjer

>0.045

25

Opening time of release

≥0.04

≥0.04

26

Motorized opening time

s

≥1

0.3

0.3

27

Opening time (motorized) of disconnecting switch

s

≥2

≥2

28

Clearance of disconnecting sv/itch and load break switch

m

>150

>150

29

Disconnecting switch and load break switch linkage mechanical life

time

>5000

>5000

30

Outline Dimension(LxWxH)

m

960x434x892

965×518(Coniains the fuse )x892